12 kJ/s, 2 - 50 kV

 12 kJ/s Power Supplies
The CCS12 Series of high voltage switching power supplies is designed to quickly charge capacitors, either small capacitances at high repetition rates, or large capacitor banks at low repetition rates. Our high frequency switchmode technology provides a compact and lightweight reliable power supply with a constant current, linear charging profile.

The many standard features and options make this series useful for laboratory and commercial applications such as lasers, medical accelerators, pulse generators, and high voltage test facilities. Designed for continuous use, these air-cooled power supplies provide an average charging rate of 12 kJ/s over 14 output voltage ranges from 2 kV to 50 kV, with either positive or negative output polarity. Output control and status monitoring are accomplished with the standard remote control interface. They can be ordered with or without instrumentation.

Model Number 1
Output Power 2
Output Voltage
Output Current
CCS12002P1H
12 kJ/s
0 - 2 kV
12 A
CCS12003P1H
12 kJ/s
0 - 3 kV
8 A
CCS12004P1H
12 kJ/s
0 - 4 kV
6 A
CCS12005P1H
12 kJ/s
0 - 5 kV
4.8 A
CCS12006P1H
12 kJ/s
0 - 6 kV
4 A
CCS12007P1H
12 kJ/s
0 - 7 kV
3.43 A
CCS12008P1H
12 kJ/s
0 - 8 kV
3 A
CCS12010P1H
12 kJ/s
0 - 10 kV
2.4 A
CCS12015P1H
12 kJ/s
0 - 15 kV
1.6 A
CCS12020P1H
12 kJ/s
0 - 20 kV
1.2 A
CCS12025P1H
12 kJ/s
0 - 25 kV
0.96 A
CCS12030P1H
12 kJ/s
0 - 30 kV
0.8 A
CCS12035P1H
12 kJ/s
0 - 35 kV
0.69 A
CCS12040P1H
12 kJ/s
0 - 40 kV
0.6 A
CCS12045P1H
12 kJ/s
0 - 45 kV
0.53 A
CCS12050P1H
12 kJ/s
0 - 50 kV
0.48 A
  1Positive polarity, instrumented, 480 VAC 3Ø input.  Other configurations available.
2Average power at maximum output voltage.
 

CCS12 Specifications

Average Charging Rate
12 kJ/s at rated Output Voltage

AC Input
400 VAC 3Ø  50/60 Hz
480 VAC 3Ø  50/60 Hz

Voltage Ranges
2, 3, 5, 6, 8, 10, 15, 20, 25, 30, 35, 40,
45, 50kV. All models continuously variable
from 0 to 100% rated voltage output.
Accuracy ± 0.5%

Polarity
Positive or Negative (factory set)

Delay After Discharge
Preset PS off-time of ~ 150 µs after load
discharge to assist HV switch recovery
(factory tailorable)

Self Protected
Overvoltage/open circuit
Overcurrent (inherent in topology)
Overtemperature

Viewset
LCD display of programmed voltage set point

Pulse to Pulse Repeatability
± 0.5% to 1 kHz

Efficiency
> 90%

Power Factor
> 0.85

Inrush Current Limit
< 10A

Ambient Temperature
Operating: 0 to 45°C
Storage: -30 to 85°C

Size
222mm tall x 482mm x 508mm deep
8.75" tall x 19" x 20" deep

Weight
< 10kV, 19 kg (42 lbs)
10-50kV, 29 kg (64lbs)

Remote Control
25-pin D-type subminiature female
socket type connector

Output Cable
18 ft HV  (other lengths available upon request)

  Options
 
  • Chassis slides - user installable
  • Remote voltage sensing (<10 kV Models) - factory Installed
  • Master/Slave Option (1 for each slave) - user installable
  • Delay After Discharge custom configuration - factory installed
  • HV Inhibit Mode: Inhibit Active Low, Logic "0" = HV inhibited - factory installed
  • HV Enable Mode: Enable Active High, Logic "1" = HV enabled - factory installed
  • HV Enable Mode: Enable Active Low, Logic "0" = HV enabled - factory installed

Application Questionnaire  |  Voltage Reversal Protection  |  Operations & Maintenance Manual
 
Specifications are subject to change without prior notice.

 


Home | Energy Products | News | Electronic Systems | General Atomics | Quality | Capacitors | Capacitor Selection Guide
Power Supplies | Pulse Power Systems | Pulse Forming Networks | Fuses | Resistors | Product Questionnaires
Product Applications | Catalogs| Links | Technical Publications | Frequently Asked Questions | RMS Current Calculator
Contact Us | End User Statement | Informational Emails | International Reps | Site Map

 
Copyright © 2003 General Atomics Electronic Systems, Inc. All rights reserved.